News & General Information
LATEST NEWS 2026
Get to know your electricity provider
Customer Charter for Residential and Small Business Customers
Ergon Energy Network and Energex publish this Customer Charter, which explains what you can expect from your power network, from outages and connections to powerlines and property poles on your land. Head Start Electrical isn’t part of either network, so contact them for faults and call us for electrical work on your property.
SMOKE ALARM UPDATE
Queensland Fire & Emergency Services says the following
FROM 1 JANUARY 2017
- Existing smoke alarms manufactured more than 10 years ago must be replaced with photoelectric smoke alarms which comply with Australian Standards (AS) 3786-2014. (Note: the date should be stamped on the back)
- Smoke alarms that do not operate when tested must be replaced immediately.
- Existing hardwired smoke alarms that need replacement, must be replaced with a hardwired photoelectric smoke alarm.
FROM 1 JANUARY 2022
All homes or units being sold or leased, or existing leases renewed, will require hardwired photoelectric, interconnected smoke alarms. Non-removable 10-year battery smoke alarms can be installed in place.
Smoke alarms in the dwelling must:
- be photoelectric (AS3786-2014); and
- not also contain an ionisation sensor; and
- Be hardwired to the mains power supply, if currently hardwired. Otherwise, smoke alarms can be either hardwired or powered by a non removable 10 yr battery or a combination of both.
- be interconnected with every other smoke alarm in the dwelling so all activate together.
The legislation requires smoke alarms must be installed in the following locations:
- on each storey
- in each bedroom
- if there is no hallway, between the bedroom and other parts of the storey; and
- if there are no bedrooms on a storey, at least one smoke alarm must be installed in the most likely path of travel to exit the dwelling.
FROM 1 JANUARY 2027
All Queensland homes — including owner-occupied properties not being sold or leased — must be fully compliant with interconnected photoelectric smoke alarms in every bedroom, hallway connecting bedrooms, and on every storey. With this deadline fast approaching, now is the time to get your smoke alarms checked.
SAFETY SWITCH INSTALLATIONS
From Worksafe Queensland
Regardless of whether you own or rent, you should consider having safety switches installed on all circuits. Safety switches protect you, your family and anyone visiting the property from electric shock. The risk is real. One safety switch may not be enough. If you are unsure, call your electrician to see if your home is safe.